Automatic Component Analyzer

Model  TH2818

Features

Specifications

Test Parameters

ZYCLXBRGDQθLKLEAKAGE INDUCTANCE

TURN-RATIOTURNPHASEDCR

Test Frequencies

20Hz to 300kHz0.01Hz StepsAccuracy: 0.01%

Test Level

5mVrmS1mVrmS SREPS(Turn-Ratio)

V Normal 5mVrms-2Vrms Constant 5mVrms-1Vrms

C Normal 5μArms-2mArms Constant 100μArms-10mArms

Output Impedance

30Ω100Ω Seletable

Accuracy

0.05%After open/short zeroing 23°C±5°C

Measurement Range

ZRX 0.01mΩ TO 99.99MΩ ... YGB 0.01nS TO 99.999S

C 0.00001pF TO 9999.99MF ....LLK 0.01nH TO 9999.99H

D 0.00001 TO 99999.9 .θ -179.999°TO 179.999°(-3.14159 Rad to 3.14159 Rad)

Q 0.01 to 99999.9

TURN-RATIO 10.01 TO 10001.. DCR 0.01mΩ TO 99.9999MΩ

Display Resolution

6-Digits Resolution

Measurement Speed

FAST32msMEDIUM100msSLOW500ms≥1KHz..

Equivalent Circuit

Series/Parallel/Auto

Ranging Mode

9 Ranges,Auto/Manual

Trigger Mode

Internal/Manual/External

Averaging Times

1 to 255Programmable

Correction Function

Open/Short PointSweep Zeroing/Load Correction

Measurement Terminals

Four-terminal pair

List Sweep

List Sweep display up to 11 points frequencylevelinner-bias volt and Ext-bias current

Inner DC Bias

DC Bias Voltage Source:0V1.5V2V Selectable

Comparator Function

11 bins for storing and bin count functions

Frequency Response Analysis

Frequency response analysis of component parameters can be acquired in any frequency range

Memory

10 groups control settingscomparator limits and list sweeping values can be stored to interal non-volatile memory

Interface

IEEE488(Option)RS-232CHANDLER(Option)

Weight

12kg Approx

Dimensions (W*H*D)

430mm*180mm*670mm